ESPE2019 Poster Category 3 Late Breaking Abstracts (69 abstracts)
1Quirón Salud Hospital, Badajoz, Spain. 2 Badajoz University Hospital, Badajoz, Spain
Introduction: Achieving metabolic control in children with type 1 diabetes (T1DM) is not an easy task. Despite the new profiles of insulins and therapies with continuous infusion, hypoglycemia continue to be the most important barrier that prevents us from correctly controlling these patients.
Close control of capillary glycaemia is important for treatment adjustment. This self-control provides us with static information about capillary glycemia at a specific time, and multiple daily controls are necessary to know the patient's glycemic profile. It is demonstrated that the greater number of capillary controls there is an improvement in HbA1c.
Some technologies have been developed, and provide us information in real time of the patient's glycemic profile, using interstitial glycemia data, which, in times of stability, can be equivalent to capillary blood glucose values. They also provide personalized alarms for each patient, allowing them to make quick decisions, they also can reduce the number of hypoglycemia and increase the degree of involvement of the patient in their day to day.
Material and Methods: Study of the effect on metabolic control (A1C) using continuous glucose monitoring devices in pediatric patients with T1DM.
We studied average A1C in the last 6 months in 182 pediatric patients, among which there is a group with continuous monitoring (Guardian®, Dexcom®, FreeStyle®) and another group with capillary blood glucose self-monitoring. In both groups there are patients in treatment with multiple doses of insulin and patients with continuous subcutaneous insulin infusion.
Performed the statistical analysis with the SPSS 19 program, comparing HbA1c means from the Levene test.
The average A1C is studied in a group of patients with continuous glucose monitoring (CGM) (n = 110) and compared with the average A1C in the group of patients without monitoring (n = 72) and as a result, there is a significant HbA1c lower in the group of patients with monitoring (7.47 vs 7.88, P <0.05). In addition, among patients with monitoring, A1C is lower in patients who use continuous subcutaneous insulin infusion (7.15 vs 7.68, P <0.05).
Conclusions: In our group of patients we can see that the use of continuous glucose monitoring improves the metabolic control in pediatric patients, and this control is optimized when we associate a continuous glucose monitoring device with an infusion system of subcutaneous insulin.